ES-Net is the base model in the ES series. It has no screen and no buzzer. Measurement, time sync, and communication match ES-Pro. For setup, see Installation and Wi-Fi setup.
The seismometer calculates Japan Meteorological Agency (JMA) instrumental seismic intensity on the device. After it boots, it must collect 60 seconds of data before it starts outputting intensity.
Filter
Details
Time-domain high-pass (HPF)
11th-order IIR, cutoff frequency about 1 Hz
Time-domain low-pass (LPF)
11th-order IIR, cutoff frequency about 10 Hz
Frequency domain (for instrumental seismic intensity)
Attenuation below 0.5 Hz and above 10 Hz, with period-effect compensation √(1/f)
NTP. It runs automatically after the device joins Wi-Fi
Sync interval
2 – 10 minutes, adjusted automatically from clock drift
Time error
Usually ±10 ms
Time accuracy
50 ppm
Networked mode and not-networked mode both sync the clock. Standalone mode does not join Wi-Fi, so it does not sync the clock, and timestamps may be inaccurate.
Three-axis acceleration (gal), 50 samples per second.
Acceleration value a (gal) used for instrumental seismic intensity, about one sample every 0.5 seconds. It can be converted to instrumental seismic intensity.
Bluetooth turns on only while you set up Wi-Fi (pairing mode) or update firmware (BLE OTA mode), so ExpTech Home can connect. During normal operation, Bluetooth is off.